Cleaning the DCX Lens
e DCX lens is located inside the M2 Encore.
If you are seeing a static aberration in your
footage, its possible there is dust on the DCX
lens. Cleaning the DCX lens should not be a
routine maintenance. It should only be done if
all other external surfaces, such as the glass of
the
microX, have already been cleaned and
examined.
1) Open-up the Encore’s top-lid by removing
the thumbscrews
2) Watch your picture, while you set the focus
of the camera towards the back (closest-by
setting)
3) Take a cotton-swab, and without touching it
with your ngers, rub it with a microber/lens
cloth until it gets uy. Apply compressed air
to the same end.
4) Hold the swab between your nger tips,
angled towards the DCX lens (you might even
want to bent the swap slightly)
5) Use the uy swab to clean the front and
back of the DCX lens (through the little
iron grate (back) and just behind the rotating
groundglass (front)
Do NOT start blowing compressed air into the
compartment, or you will probably have to start
over again as something else may be blown up
and stick to it.
microTips:
The procedure above will also reduce the electrostatic load of
the condenser lens. Because the groundglass rotates through
the stationary air, an electrostatic eld is formed. It can be
both friend and foe; dust particles will stick to certain parts
of the mechanism and stay there, OR it will attach to the
condenser lens and stay there., which will than cause you to
repeat this cleaning routine.